Quantcast
Channel: VMware Communities: Message List - vCenter™ Server
Viewing all articles
Browse latest Browse all 15787

Re: vCenter Alarm for Physical NIC linkstate down

$
0
0

The 1000v is a dvSwitch and there is actually an extra trigger for this, however it might not be configured as an alarm by default.

Create a new host alarm definition or edit an existing one, monitoring for events and set the trigger to:

Network Redundancy Degraded on DVPorts


Also you can configure an alarm on the "Physical NIC vmnic6 linkstate is down" event as well.

For this set the trigger to:

esx.problem.net.vmnic.linkstate.down

 

The following trigger catches the "Link up" event:

esx.clear.net.vmnic.linkstate.up